Описание

Spot Type Main Unit, Gun Attachment Supported
Model SJ-M040
Type Head
Voltage application method Pulse AC method
Applied voltage ±5.5 kV
Rated output voltage ±6 kV
Ion balance control method I.C.C. method
Ion balance ±30 V*1
Maximum air pressure 0.7 MPa
Connection tube Outer diameter: 6 mm, Inner diameter: 4 mm
Major functions Condition alert output, Ion level alert output, Alarm output, Ion balance adjustment function, Solenoid valve control function
Control input Trigger input Non-voltage input
Control output Alarm output NPN open-collector
Ion level/condition alert 100 mA (40 V max.)
Rating Power voltage 24 VDC ±10 %
Current consumption 450 mA or less
Environmental resistance Ambient temperature 0 to +40 °C
Relative humidity 35 to 65 % RH (No condensation)
Weight Static elimination head Approx. 650 g
Controller Approx. 300 g
*1 With an operating distance of 150 mm and air purge is not used.
''