Most accurate power measurements for reference applications and use in calibration labs
Key Facts
  • Measurement range: –35 dBm to +20 dBm
  • Frequency range: DC to 40 GHz
  • 2.92 mm connector
  • Operation with R&S®NRP2 base unit or via USB on a Laptop/PC
  • Outstanding linearity of 0.007 dB (0.16%)
  • Industry-proven DC-coupled thermoelectric test cell
  • Sophisticated connector design
  • Best SWR at 40 GHz (1.25)
  • Excellent impedance matching

Brief Description Thermal power sensors are especially used for complex measurement tasks. They feature higher accuracy and tolerate any type of modulation. To improve measurement accuracy, the hardware of the R&S®NRP-Z5x thermal power sensors is designed to reduce measurement noise to a minimum and to make the sensor immune to thermal environmental effects. These sensor characteristics are particularly beneficial in reference applications and calibration labs.
Specifications
Thermal Power Sensor
 
Frequency range Power measurement range, maximum input power Impedance matching (SWR) Rise time, video BW Uncertainty for power measurements at +20 °C to +25 °C (1) absolute (in dB) (2) relative (in dB)
R&S®NRP-Z51, N connector
DC to 18 GHz 300 nW to 100 mW (–35 dBm to +20 dBm) max. 300 mW (AVG)/ 10 W (PK, 1 ?s) DC to 100 MHz: <1.03>100 MHz to 2.4 GHz: <1.06>2.4 GHz to 12.4 GHz: <1.13>12.4 GHz to 18.0 GHz: < 1.16 (1) 0.040 to 0.082 (2) 0.010
R&S®NRP-Z52, 3.5 mm connector
DC to 33 GHz 300 nW to 100 mW (–35 dBm to +20 dBm) max. 300 mW (AVG)/ 10 W (PK, 1 ?s) DC to 100 MHz: <1.03>100 MHz to 2.4 GHz: <1.06>2.4 GHz to 12.4 GHz: <1.13>12.4 GHz to 18.0 GHz: <1.16>18.0 GHz to 26.5 GHz: <1.22>26.5 MHz to 33 GHz: < 1.28 (1) 0.040 to 0.101 (2) 0.010
R&S®NRP-Z55, 2.92 mm connector, model .03
DC to 40 GHz 300 nW to 100 mW (–35 dBm to +20 dBm) max. 300 mW (AVG)/ 10 W (PK, 1 ?s) DC to 100 MHz: <1.03>100 MHz to 2.4 GHz: <1.06>2.4 GHz to 12.4 GHz: <1.13>12.4 GHz to 18.0 GHz: <1.16>18.0 GHz to 26.5 GHz: <1.22>26.5 MHz to 40 GHz: < 1.28 (1) 0.040 to 0.108 (2) 0.010
R&S®NRP-Z55, 2.92 mm connector, model .04
DC to 44 GHz 300 nW to 100 mW (–35 dBm to +20 dBm) max. 300 mW (AVG)/ 10 W (PK, 1 ?s) DC to 100 MHz: >100 MHz to 2.4 GHz: <1.06>2.4 GHz to 12.4 GHz: <1.13>12.4 GHz to 18.0 GHz: <1.16>18.0 GHz to 26.5 GHz: <1.22>26.5 MHz to 40 GHz: <1.28>40 GHz to 44 GHz: < 1.30 (1) 0.040 to 0.138 (2) 0.010
R&S®NRP-Z56, 2.40 mm connector
DC to 50 GHz 300 nW to 100 mW (–35 dBm to +20 dBm) max. 300 mW (AVG)/ 10 W (PK, 1 ?s) DC to 100 MHz: <1.03>100 MHz to 2.4 GHz: <1.06>2.4 GHz to 12.4 GHz: <1.13>12.4 GHz to 18.0 GHz: <1.16>18.0 GHz to 26.5 GHz: <1.22>26.5 MHz to 40 GHz: <1.28>40 GHz to 50 GHz: < 1.30 (1) 0.040 to 0.143 (2) 0.010
R&S®NRP-Z57, 1.85 mm connector
DC to 67 GHz 300 nW to 100 mW (–35 dBm to +20 dBm) max. 300 mW (AVG)/ 10 W (PK, 1 ?s) DC to 100 MHz: <1.03>100 MHz to 2.4 GHz: <1.06>2.4 GHz to 12.4 GHz: <1.13>12.4 GHz to 18.0 GHz: <1.16>18.0 GHz to 26.5 GHz: <1.22>26.5 MHz to 40 GHz: <1.28>40 GHz to 50 GHz: <1.30>50 GHz to 67 GHz: < 1.35 (1) 0.040 to 0.248 (2) 0.010
R&S®NRP-Z58, 1.00 mm connector
DC to 110 GHz 300 nW to 100 mW (–35 dBm to +20 dBm) max. 300 mW (AVG)/ 10 W (PK, 1 ?s) DC to 100 MHz: <1.05>100 MHz to 2.4 GHz: <1.08>2.4 GHz to 12.4 GHz: <1.18>12.4 GHz to 18.0 GHz: <1.23>18.0 GHz to 26.5 GHz: <1.28>26.5 MHz to 40 GHz: <1.38>40 GHz to 50 GHz: <1.46>50 GHz to 67 GHz: <1.56>67 GHz to 80 GHz: <1.60>80 GHz to 95 GHz: <1.66>95 GHz to 110 GHz: < 1.70 (1) 0.040 to 0.318 (2) 0.014
''